Frequently asked questions

All Reagents Xmatrx Elite and Infinity ISH Probes and Detection Kits Ancillary Reagents Antibodies and Detection Kits Instrumentation

Yes, fluorescent microscope with specific filters depending upon fluorescent colors that the customer is using for their study.


No. The customer has to purchase fluorescent tagged secondary antibodies from other companies.


Yes


Yes, IF can be performed in every BioGenex Open instruments like Xmatrx Infinity, NANO VIP & i6000 Infinity. Customer has to create his/her own IF protocol in BioGenex instruments.


Both IHC (Immunohistochemistry) and IF (Immunofluorescence) have same functions. However, IF is the staining method usually used for multiplexing, particularly when co-localization is required or when 2 or more than 2 different antibodies needs to be detected on a single tissue.

IF follows the protocol same like IHC with slight modifications. The basic differences between IHC and IF is the use of fluorescent tagged (conjugated) antibodies in IF which may have colors like FITC, PE, Cy3, Cy5, Texas Red etc. are attached either with primary antibodies or secondary antibodies. After that there is no chromogen required here and final mounting with DAPI follows. For visualization, fluorescent microscope is also required.


40 Individual protocols can be performed in one single run on Xmatrx


Both super enhancer and Poly-HRP is used in two step kit and One step kit do not have super enhancer.


60oC for 1 hr


Hematoxylin


Positive


AXXXX-5ME-6ml, AXXXX-10ME-10ml, AXXXX-YCDE-16ml, XU328-UCE-1 ml, XU328-5UCE-0.5ml


20mL


Barcode


5±0.5Pa


4 Liters


8 Liters


2 Attempts


Deparaffinization, Rehydration


6 Slides


20 Slides


Ambient – 105⁰C


QD410-YCDE


60 reagents


60 Slides at a time


Barcode


1/3rd test area, 2/3rd test area, Full test area


40 Slides


2 rack X30 vials


<1min


100ul -1000ul


Baking, deparaffinization, Antigen retrieval and final coverslipping.

  • EZ-retriever can perform
  • De-Waxing, Rehydration, Antigen retrieval

Epitope


49 Reagents


Ambient to 107oC


96 Slides


25X40 Barrier slides


AM/AN/AR-XXX-5M


100-120µL


BioGenex antibodies are suspended in antibody diluent contains BSA. It does not contain latex.


It is a super sensitive wash buffer.


Yes, customer will have to standardize the protocol for the same.


Avidin/Biotin Block blocks all endogenous biotin, biotin receptors, and avidin binding sites present in tissues.


A few of the antibodies work on Ventana.


Yes


Power block is based on BSA and protein block is based on Horse serum.


Wash with DI water


Antibodies works well on cell smears but one has to standardize the protocol for the same.


Citric acid based AR solution pH is around 6.0-6.2 and Tris EDTA based AR solution pH is around 9.0.


Yes


Yes, antibodies may work for western blot.


Clear mount is Aquous and X-mount is non-Aquous.


Polymer HRP is streptavidin and biotin free and link –label contains streptavidin and biotin.


You can use BioGenex double staining kit or you can use one poly HRP and second Poly AP antibody for mouse and rabbit antibody respectively.


For RTU 1-3 µg/ul


Check the antibody dilution, incubation time, other reagents and protocol for the particular antibody.


IHC, ISH, FISH, IF, ICC


Do as recommended by chemical waste disposal authority.


Yes, it produces DAB waste, and it is carcinogenic.


At 4°C it will not solidify.


At 4°C


QD550-YCDE, QD550-YCXE, QD610-YADEN


Just before starting the run.


No, you can fill only the required buffer carboys.


No


No


16ml


1ml


For Xmatrx vial it is 400ul, for i6000 vial it is 500ul, for NanoVIP vial it is 400ul.


For close system you need to use only Biogenex products because we have a no. of standardized protocol for IHC, ISH and FISH in close system.


Barcoded reagents are for use with close system. After reading the barcode, instrument will starts the run. It helps in removing the human errors. Accurate & precise real-time reagent tracking on Xmatrx and i6000 is done using barcode.


Yes, in open system you can use third party/your antibodies. In closed systems like Xmatrx Elite and i6000 Diagnostics, there is a provision to use third party/own antibodies on BioGenex BARCODED USER DEFINED vials.


EZ-AR1/AR2 Elegance on automation and EZ-RT system and EZ-AR 1/AR 2 for manual and EZ-RT system.


Yes you can do antigen retrieval on system (Xmatrx, Xmatrx MINI, NANO, and NANO VIP). On i6000 you cannot do antigen retrieval on instrument. For i6000, you will need BioGenex EZ-RT system.


You can use alcohol on the instrument. We do not recommend use of Xylene on automation.


You can use dewaxing online/offline. It’s up to your convenience.


You can use any of the standard paraffin wax.


Yes, you need to take barrier slides from BioGenex specially design for the Xmatrx to create microchamber.


Yes, we can however some steps need to be modified by the customer.


Yes


Yes


Yes


Yes


No


Microchamber


Yes


No, it is not required. The system has already 400+ preloaded protocols and protocols for 3rd party antibodies. One can only change/edit incubation time and wash number and times.


We are providing User Defined Barcoded Empty vials. The customer has to buy those to run 3rd party antibodies.


100 slides per day (60 slides in eight-hour shift and 40 slides in delayed overnight run)


Yes


Yes


Yes


  • Temperature: 15-30oC
  • Humidity: 15-55% RH

30min for 96 slides


Microwave


550+


Xmatrx MINI


  1. Xmatrx MINI
  2. Xmatrx NANO
  3. NANO VIP
  4. Xmatrx Elite
  5. Xmatrx Infinity

20 tests


10 tests, 20 tests


  1. eFISH Histo (DF500-20X)
  2. eFISH Cyto (DF510-20X)

NANO VIP is a complete automatic instrument but Xmatrx NANO is a semi-automatic one where the reagent dispensing is manual. Rest of the functions is similar


10


It is used for Barcodedslide label printing


  1. Xmatrx Elite
  2. i6000 Diagnostics

  1. Xmatrx Infinity
  2. i6000 Infinity
  3. NANO VIP
  4. Xmatrx MINI

  • 60tests
  • 500tests
  • 1000test

  • AC (Antibody Cocktails)
  • AM (Mouse Monoclonal Antibodies)
  • AN (Rabbit Monoclonal Antibodies)
  • AX, AY (Monoclonal Antibodies for Xmatrx®)
  • AW (Polyclonal Antibodies for Xmatrx®)
  • AR (Polyclonal Antibodies)
  • MU (Mouse Monoclonal Antibodies)
  • NU (Rabbit Monoclonal Antibodies)
  • PU (Polyclonal Antibodies)

  1. Dewaxing/Deparaffinization solution
  2. Buffer and enzymes for antigen retrieval
  3. Buffers and consumables like tips, coated slides, vials
  4. Antibodies
  5. IHC Detection kits
  6. Mounting media
  7. ISH probes, miRNA probes
  8. ISH detection kits
  9. FISH probes
  10. FISH detection kits
  11. Blocking Reagents
  12. Automated instrument for IHC, ISH, FISH
  13. Covid-19 RT-PCR detection kit
  14. VTM

ISH- ISH has broad applications such as physical chromosome mapping, karyotyping, and pathogen profiling. Riboprobe also enables the localization and analysis of gene expression profile.

FISH- As a diagnostic tool, FISH is widely used in clinical genetics, neuroscience, reproductive medicine, toxicology, microbial ecology, evolutionary biology, comparative genomics, cellular genomics and chromosome biology to check for genetic abnormalities associated with prenatal diagnosis, cancer, birth defects and mental retardation. It is possible to differentiate benign and malignant tumors in the same tissue using FISH.


  • Chromogenic ISH: Bright field microscope
  • FISH: Fluorescence microscope

There are two basic approaches to visualize the DNA or RNA target sequences in situ: chromogenic in situ hybridization (CISH) and fluorescence in situ hybridization (FISH). While these approaches involve the same underlying principle, the instrumentation required to visualize the specimen is different.


The nucleic acids within a histologic specimen can be detected by the hybridization of a complementary nucleic acid probe in which a reporter molecule is attached. Common non-radioactive labels for probe are fluorescein and digoxigenin. Subsequent visualization of the reporter molecule localizes DNA or RNA sequences in tissue or cells samples.


In Situ Hybridization (ISH) is a powerful technique for precise detection and localization of a specific nucleic acid sequence within a histologic section.


  • Horseradish peroxidase (HRP)
  • Alkaline phosphatase

Antibody is conjugated to an enzyme, such as peroxidase, that can catalyze a color-producing reaction. Antibody can be tagged to a fluorophore, such as fluorescein (immunofluorescence)


These are foreign molecules to which the body may be exposed and respond with a reaction specifically and bind to the antigen. These are typically proteins or polysaccharides within or on the surface of cell.


These are antibodies against single epitope of single antigen


These are antibodies against many epitopes of one antigen


  1. Enzymatic/proteolytic antigen retrieval
  2. Heat-induced antigen retrieval method

The process of sample fixation can lead to protein cross-linking, which masks antigens and can restrict antigen-antibody binding. Antigen retrieval enables an antibody to access the target protein within the tissue.


Biogenex provides Dewax solution for deparaffinization. It is a non-toxic solution. Commonly Xylene is used but it is a toxic solution.


3-5µ


10% Neutral Buffered Formalin


  1. Baking
  2. Deparaffinization and rehydration
  3. Antigen Retrieval
  4. Peroxide Blocking/Endogenous peroxidaseblocking
  5. Power Blocking/Protein Blocking
  6. Primary Antibody
  7. Super Enhancer/Linker
  8. Poly-HRP/ Secondary Antibody/ Label
  9. DAB
  10. Counter staining
  11. Dehydration, Clearing and mounting

Note– If one is using one step poly HRP then “vii” point is not applicable.


Immunohistochemistry is used to help diagnose diseases, such as cancer. It may also be used to tell the difference between different types of cancer.


Immunohistochemistry is a well-established, highly specific and sensitive method that allows the localization of an antigen within a cell or any other biological tissue samples with high resolution. The bound antigen-antibody complexes are then visualized using chemically linked enzymes, dyes, or fluorescent labels.


Yes, it will be added based on Special request from customers-end and you need to contact BioGenex, Customer Service @ 1 800 421 4149, if not then FISH cannot be performed on Elite System.


No, Infinity will proceed without the barcodes slides and reagents scanning


Elite: No, only the Slides labels can be printed with i500 printer, whereas the Detection kit needs to be purchased from BioGenex only.


400 lb /182 Kg


Dimensions are 29 x 66 x 59 Inches


Yes, the Neutral to Earth Voltage should be always less than 2 Volts (AC) for the Medical instruments.


Yes, without any change user can plug the instrument power to 110V or 230V power Supply from UPS.


No, it’s always better to arrange from the User End.


Yes, either needs to connect to the Centralized UPS or the Separate UPS with 1500Watts. If the Power Failure rate is more then, it’s better to connect to longer UPS Back up.


XMatrx is developed and tested on Windows XP / Win 7 and Win 10. Currently providing with Win 10 Operating System


Graphical User Interface for Xmatrx is based on our popular i6000 interface. Xmatrx GUI expands the i6000 interface to enrich your programming experience. Main interface window displays the slide map and control panel. Slide map offers an intuitive and convenient way of selecting & editing slide protocols and to query the progress of a slide during the run.

Various operations are color-coded. Slide objects on the main window are displayed in appropriate colors based on their current operation making it convenient to get a snapshot of the run status from a distance. In the event of an error condition, system plays out an appropriate audio message and also visual message on the control panel.


Need for updates/bug fixes, if any, determines the frequency of new software releases.  There could be 1-2 releases every 10 – 12 months.


Instrument is calibrated before shipping out. While setting up the system, calibration must be checked. Once setup, re-calibration is not required for day-to-day operation. PM will address the calibration issues, if any.


Each PC that ships with XMatrx will be configured for remote access capability. If a PC is connected to Internet, with required access rights, remote diagnostic can be performed. 


Infinity: Xmatrx allows you to create your own protocols in addition to BioGenex supplied ones.

Elite: Being a closed system, Xmatrx Elite requires you to run all the protocols (BioGenex and User created) in a closed format. Once a protocol is scanned into a slide position, you can edit the allowed fields, if needed. Allowed fields are: Temperature, Incubation, Buffer Selection, number of Count &Micro Chamber sealing.


No. All consumables must be purchased from BioGenex only


Xmatrx System requires a Special Micro Chamber Slides with hydrophobic barrier, after oil sealing it canwith-stand longer incubation time and very minimal reagent usage. These slides are in 3 different Patterns (18 x 18mm, 25 x 25mm and 25 x 40mm). These slides need to be purchased from BioGenex only.


There are Two8 liter waste containers attached to the Xmatrx Instrument and for disposing the Waste need to follow the “Waste Management Process” specified as per the LAB standards or follow  any regular biohazard waste Procedure


Yes the Xmatrxä System will mount the slides using permanent mounting media. (Xmountä) Once the mounting media is applied it will also add the Coverslip


It is recommended that you prime the required solutions before every run for consistent staining quality. If it is not possible, you may want to prime the solutions whenever you make up new reagents or operate the system after a long period of inactivity (e.g., 2-3 days). This eliminates the air bubbles in the buffer lines and ensures continuous flow of the buffer solutions.


No. Xmatrx system displays the required buffers in the pre-run prime window. Disconnect the unused buffer lines from the system before starting a run.


Approximately 100 ml


Yes,pleasecontact BioGenex, Customer Service @ 1 800 421 4149.


Xmatrx system is designed to work with 3 different sizes of Coverslips:

  • 18 x 18 mm
  • 25 x 25 mm
  • 25 x 40 mm

No. System discards the tips and Coverslips after use. Reuse of these discarded tips and Coverslips is not recommended, as it will cause cross contamination and also damages the instrument functionality.


While applying large volumes (more than 100ul), Xmatrx system uses large tips. Typically, volume range for this step is 100-850ul. 


While processing expensive reagents like AR Solution, Antibody/Probe, Xmatrx system uses small tips. Typically, volume range for this step is 10-100ul.


Yes, for Xmatrx we have Consumable kit which has Barrier Slides, Small and Large Pipette tips and coverslips.

Please contact BioGenex, Customer Service @ 1 800 421 4149. 


Elite: No. The Xmatrx Elite is a closed system, which ensures that the user will have the best and optimal results using BioGenex detection systems.

Infinity: Yes, it’s open System.Can create a New Reagent, Antibody or increase the number of steps in the protocol or can create new Protocols also.


Xmatrx system can be programmed to use as much as 850ul. However, different applications & operations may have different maximums. Please refer to the protocol datasheet for volume information on a specific protocol.


Xmatrx system can be programmed to use as little as 10ul. However, different applications & operations may have different minimums. Please refer to the protocol datasheet for the volume information on a specific protocol.


Different vial types have different dead volumes:

  • 17 ml vials have a dead volume of 400ul
  • 2 ml vials  for ISH have a dead volume of 50ul 

When the system does not read the Reagent Vial, user may have the provision to add manually (enter the serial number) by selecting the reagent from the list. A reagent vial is entered into the list either or when the system reads the Barcoded vial for the first time. If the reagent does not exist in the database, the vial will have to be returned back to BioGenex, to be replaced by a new vial. Please contact BioGenex Technical Support @ 1 800 421 4149 for more information.


When the system does not read the slide barcode label, the user may manually select the protocol from the internal database of BioGenex protocols.


Yes. Please contact BioGenex’s, Customer Service @ +1 510 824 1400 


BioGenexsells Xviz detection system, which is be used to run all antibodies. The Xmatrx Elite is a closed system, which ensures that the user will have the best and optimal results using BioGenex detection systems. Xmatrx Infinity is an Open System, all the Detection kit and Antibodies can be used as per customer choice.


This allows the system to track reagent usage, lot numbers and expiry to ensure that the correct reagent is being used for Xmatrx Elite only.


BioGenex sells most of the antibody panels that are required in a clinical lab. In case, if any antibody is not available fromBioGenex, the User will have an option to buy an empty Barcoded vial to run their own Antibody for Elite. In Case of Infinity instrument 3rd Party Antibody can be used without the Barcoded vial.


< 2 Minutes


Yes. The slide heaters are individually temperature controlled.


Yes you can do antigen retrieval on the system.


No.  Xylene is not recommended, better to use BioGenex De-waxing solution.


Yes, the slides can be baked on the Xmatrx System @ 60°C for 1 hour and also you have the flexibility to adjust the Temperature and Time. Apart from this the protocol can be used for baking along with instrument starts and finishing the run.


You can order them through Customer Service +1 510 824 1400or email to customerservice@biogenex.com; or indiacs@biogenex.com or internationalcs@biogenex.com


Yes they just need to be placed in the slots on the base of the instrument.


BioGenex has designed the Slide racks for the Xmatrx System. The slides just need to be place into the Slide holder slot and then close the clip.


The best allowed temperature range for the instrument is 15°C to 30°C.


BioGenex Technical Support @ 1 510 824 1400 should be able to answer all your technical questions or customerservice@biogenex.com; or indiacs@biogenex.com or internationalcs@biogenex.com

You may also contact your local Sales Representative OR/and Application Specialist


BioGenex field Service engineer / trained distributor will perform Two PM’s per year


This includes just a basic cleaning of the instrument to prevent any contamination and to ensure proper functionality of the instrument. We recommend basic cleaning done by the user as per the Maintenance Chart.


Xmatrx Elite / Infinity is provided with a standalone systems. So the user will not require any extra bench space. The unit will be received as a cabinet with all the bulk reagents placed within it.


No the instrument does not need to be under a hood.


No you do not need to calibrate the instrument every time you use it. The instrument will be calibrated when it is installed. Re-calibration will be required if the instrument is moved to a different location.


BioGenex field service engineer will install the instrument. Your local sales repsentative and application scientist will be involved in training and optimizing your protocols on the instrument.


FFPE tissues, pap smears and cell smudges can be used with these probes.


We provide a universal detection kit for all probes (Super SensitiveTM One-Step ISH detection kit).


BioGenex probes are intended to use with Super SensitiveTM One Step ISH detection kit and optimized for chromogenic visualization under bright field microscopy. However, if the end-user wants to use any other kit and visualization technique, they need to validate their own protocol.


For the less no. of slides, if you are using BioGenex antigen retrieval solutions {HK546 (EZ-AR™ 1 Elegance ), HK547 (EZ-AR™ 2 Elegance)}, you can reuse these solutions up to 2-3 times.


Following are the solutions for doing Antigen Retrieval without EZ-RT System and Microwave-

  1. Water bath- Set the temp. of water bath at 100’C. Take one glass/plastic container and pour AR solution in it. Thereafter put the slides (with slide holder) in glass/ plastic container. After that put this container (having slides) into water bath for 30 mins. Make sure that the water bath water should not mix with the AR solution container. Heat at 100’C for 30-40 min and take out the container from water bath. Thereafter follow the regular IHC protocol.
  2. Hot plate- Set the temp. 100’C. Take AR solution in glass container and then put slides into glass container. Put that glass container at hot plate and heat for 30-40 min at 100’C. Thereafter follow the regular IHC protocol.

Note- Count the time of AR once AR solution temp reaches to 100’C. If it is not possible to reach to 100’C then it can be done at 98’C also.


The choice of mounting medium following immunochemical staining is largely dictated by the chromogen label used to visualize the antigen. Compatible Mounting Media for Chromogens and Counterstains

Counterstains AEC BCIP/NBT DAB Elegance Red Fast Red New Fuchsin
Hematoxylin Aqueous/ SuperMount Aqueous /Not recommended Aqueous/ Permanent/ SuperMount Aqueous/ Permanent/ SuperMount SuperMount / Aqueous SuperMount
Methyl Green Not recommended Permanent Permanent Permanent Permanent Permanent
Nuclear Fast Red Not recommended Aqueous/ Permanent/ SuperMount Aqueous/ Permanent/ SuperMount Not recommended Not recommended Not recommended

 


Most antibodies can be used either with DAB or AEC chromogen depending on the preference for staining under a light microscope.


The requirement of antigen retrieval depends on the antibody used and its staining protocol. For frozen and de-calcified tissues, heat-based antigen retrieval is NOT recommended. We provide alternate solutions for these kinds of tissues such as the Decal Retrieval Solution for acid-decalcified bone marrow tissue and enzymes for tissue digestion.


The proprietary technology used in the EZ-AR Elegance solutions provides stronger intensity and reproducible results. These solutions are designed for used with automated platforms such as Xmatrx systems and the EZ Retriever. The normal antigen solutions are intended for use with manual protocols.


Evaporation in Citra and Citra plus antigen retrieval solution is more and its ph also changes after use that’s why these can not be reused again and again.


For concentrated antibodies, the protein concentration is available on the data sheet for that specific antibody. Ready-to-Use (RTU) antibodies are pre-diluted for optimal staining results. We can provide the concentration of RTU antibodies upon request.


There are various reasons as to why we discontinue certain antibodies ranging from raw material issues to insufficient sales. The replacement products, if available, can be provided on request.


Most primary antibodies raised in mouse (IgG +IgM) and rabbit (IgG) work with our Poly-HRP Secondary antibody. In case of primary antibodies raised in other species, we also provide species-specific secondary antibodies for use with our Link-Label System.


The one-step detection kit is designed with proprietary technology which eliminates the use of Super Enhancer required by the two-step detection kit. Therefore, the one-step kit provides superior sensitivity and specificity with the advantage of a short protocol.


Two years from date of manufacture when stored according to the product information page.


The detection kits are designed for use in human tissue. However, the Super SensitiveTM Link-Label IHC detection system comes in a choice of kit formats designed for use with human, animal or rodent tissue.


BioGenex antibodies are tested and validated for IHC. For any procedure or technique apart from IHC, the protocol must be validated by the user.


Yes, BioGenex detection kits are universal detection systems for mouse and rabbit antibodies.


Yes, most of our antibodies come in manual and automation packs and can be used for both purposes.


All of our antibodies can be used with the following detection kits provided by BioGenex:

Super Sensitive Polymer-IHC Detection System
Super Sensitive One-Step Polymer-HRP Detection System
Super Sensitive Link-Label IHC Detection System


BioGenex antibodies are validated and intended for use on human FFPE and frozen tissues. If used on tissues from other species, the protocol must be validated by the end user.


While using the EZ-Retriever®System for antigen retrieval, you have the facility to increase and decrease the temp and time according to your need. You can use 107 Deg C maximum temperature and 15 mins maximum time in one cycle with BioGenex antigen retrieval solutions {HK521 (EZ-AR™ 1), HK546 (EZ-AR™ 1 Elegance), HK522(EZ-AR™ 2), HK547 (EZ-AR™ 2 Elegance)}. If you are using other solutions then you can use it at 95 Deg C for 10 min in one cycle.


BioGenex provides information on the specific antigen retrieval solution recommended for use with its primary antibodies. We offer Retrievit Sampler Kit for use with primary antibodies from other manufacturers. This kit provides the customer with five different antigen retrieval solutions so the user can determine which one is the best for that particular antibody.


The microwave pressure cooker method is a procedure that utilizes a microwave with a pressure cooker for antigen retrieval and staining. The pressure cooker sold by BioGenex is especially designed for use in a microwave oven. Its advantages include the speed of treatment, reproducibility of results with large batches of slides, ability to use metal slide racks, and economy of equipment costs.


STAT (Latin: statum, meaning: to rush, urgent) Access allows the addition of emergency specimen slides for staining during an ongoing run. STAT slides will be processed and completed at the highest priority. During the processing of STAT slides, all other slides being processed shall remain on hold and are buffered regularly to keep the tissue hydrated. After completion of the STAT slides, all pending slides that are on hold will be processed according to their protocol.


Most autostainers on the market do not allow for the addition of new samples for staining when a run is in progress. Xmatrx Diagnostics breaks this limitation by enabling continuous operation of the system. The user can add new slides in the middle of a run if empty slide positions are available. The slides that are loaded in continuous mode will be processed along with the current slides without affecting the current run. Continuous Access enables the user to remove completed slides and load new ones without the need to wait for run completion. In addition, reagents that are no longer required can be removed and new ones can be added.


Yes, fluorescent microscope with specific filters depending upon fluorescent colors that the customer is using for their study.


No. The customer has to purchase fluorescent tagged secondary antibodies from other companies.


Yes


Yes, IF can be performed in every BioGenex Open instruments like Xmatrx Infinity, NANO VIP & i6000 Infinity. Customer has to create his/her own IF protocol in BioGenex instruments.


Both IHC (Immunohistochemistry) and IF (Immunofluorescence) have same functions. However, IF is the staining method usually used for multiplexing, particularly when co-localization is required or when 2 or more than 2 different antibodies needs to be detected on a single tissue.

IF follows the protocol same like IHC with slight modifications. The basic differences between IHC and IF is the use of fluorescent tagged (conjugated) antibodies in IF which may have colors like FITC, PE, Cy3, Cy5, Texas Red etc. are attached either with primary antibodies or secondary antibodies. After that there is no chromogen required here and final mounting with DAPI follows. For visualization, fluorescent microscope is also required.


40 Individual protocols can be performed in one single run on Xmatrx


Both super enhancer and Poly-HRP is used in two step kit and One step kit do not have super enhancer.


60oC for 1 hr


Hematoxylin


Positive


AXXXX-5ME-6ml, AXXXX-10ME-10ml, AXXXX-YCDE-16ml, XU328-UCE-1 ml, XU328-5UCE-0.5ml


20mL


Barcode


5±0.5Pa


4 Liters


8 Liters


2 Attempts


Deparaffinization, Rehydration


6 Slides


20 Slides


Ambient – 105⁰C


QD410-YCDE


60 reagents


60 Slides at a time


Barcode


1/3rd test area, 2/3rd test area, Full test area


40 Slides


2 rack X30 vials


<1min


100ul -1000ul


Baking, deparaffinization, Antigen retrieval and final coverslipping.

  • EZ-retriever can perform
  • De-Waxing, Rehydration, Antigen retrieval

Epitope


49 Reagents


Ambient to 107oC


96 Slides


25X40 Barrier slides


AM/AN/AR-XXX-5M


100-120µL


BioGenex antibodies are suspended in antibody diluent contains BSA. It does not contain latex.


It is a super sensitive wash buffer.


Yes, customer will have to standardize the protocol for the same.


Avidin/Biotin Block blocks all endogenous biotin, biotin receptors, and avidin binding sites present in tissues.


A few of the antibodies work on Ventana.


Yes


Power block is based on BSA and protein block is based on Horse serum.


Wash with DI water


Antibodies works well on cell smears but one has to standardize the protocol for the same.


Citric acid based AR solution pH is around 6.0-6.2 and Tris EDTA based AR solution pH is around 9.0.


Yes


Yes, antibodies may work for western blot.


Clear mount is Aquous and X-mount is non-Aquous.


Polymer HRP is streptavidin and biotin free and link –label contains streptavidin and biotin.


You can use BioGenex double staining kit or you can use one poly HRP and second Poly AP antibody for mouse and rabbit antibody respectively.


For RTU 1-3 µg/ul


Check the antibody dilution, incubation time, other reagents and protocol for the particular antibody.


IHC, ISH, FISH, IF, ICC


Do as recommended by chemical waste disposal authority.


Yes, it produces DAB waste, and it is carcinogenic.


At 4°C it will not solidify.


At 4°C


QD550-YCDE, QD550-YCXE, QD610-YADEN


Just before starting the run.


No, you can fill only the required buffer carboys.


No


No


16ml


1ml


For Xmatrx vial it is 400ul, for i6000 vial it is 500ul, for NanoVIP vial it is 400ul.


For close system you need to use only Biogenex products because we have a no. of standardized protocol for IHC, ISH and FISH in close system.


Barcoded reagents are for use with close system. After reading the barcode, instrument will starts the run. It helps in removing the human errors. Accurate & precise real-time reagent tracking on Xmatrx and i6000 is done using barcode.


Yes, in open system you can use third party/your antibodies. In closed systems like Xmatrx Elite and i6000 Diagnostics, there is a provision to use third party/own antibodies on BioGenex BARCODED USER DEFINED vials.


EZ-AR1/AR2 Elegance on automation and EZ-RT system and EZ-AR 1/AR 2 for manual and EZ-RT system.


Yes you can do antigen retrieval on system (Xmatrx, Xmatrx MINI, NANO, and NANO VIP). On i6000 you cannot do antigen retrieval on instrument. For i6000, you will need BioGenex EZ-RT system.


You can use alcohol on the instrument. We do not recommend use of Xylene on automation.


You can use dewaxing online/offline. It’s up to your convenience.


You can use any of the standard paraffin wax.


Yes, you need to take barrier slides from BioGenex specially design for the Xmatrx to create microchamber.


Yes, we can however some steps need to be modified by the customer.


Yes


Yes


Yes


Yes


No


Microchamber


Yes


No, it is not required. The system has already 400+ preloaded protocols and protocols for 3rd party antibodies. One can only change/edit incubation time and wash number and times.


We are providing User Defined Barcoded Empty vials. The customer has to buy those to run 3rd party antibodies.


100 slides per day (60 slides in eight-hour shift and 40 slides in delayed overnight run)


Yes


Yes


Yes


  • Temperature: 15-30oC
  • Humidity: 15-55% RH

30min for 96 slides


Microwave


550+


Xmatrx MINI


  1. Xmatrx MINI
  2. Xmatrx NANO
  3. NANO VIP
  4. Xmatrx Elite
  5. Xmatrx Infinity

20 tests


10 tests, 20 tests


  1. eFISH Histo (DF500-20X)
  2. eFISH Cyto (DF510-20X)

NANO VIP is a complete automatic instrument but Xmatrx NANO is a semi-automatic one where the reagent dispensing is manual. Rest of the functions is similar


10


It is used for Barcodedslide label printing


  1. Xmatrx Elite
  2. i6000 Diagnostics

  1. Xmatrx Infinity
  2. i6000 Infinity
  3. NANO VIP
  4. Xmatrx MINI

  • 60tests
  • 500tests
  • 1000test

  • AC (Antibody Cocktails)
  • AM (Mouse Monoclonal Antibodies)
  • AN (Rabbit Monoclonal Antibodies)
  • AX, AY (Monoclonal Antibodies for Xmatrx®)
  • AW (Polyclonal Antibodies for Xmatrx®)
  • AR (Polyclonal Antibodies)
  • MU (Mouse Monoclonal Antibodies)
  • NU (Rabbit Monoclonal Antibodies)
  • PU (Polyclonal Antibodies)

  1. Dewaxing/Deparaffinization solution
  2. Buffer and enzymes for antigen retrieval
  3. Buffers and consumables like tips, coated slides, vials
  4. Antibodies
  5. IHC Detection kits
  6. Mounting media
  7. ISH probes, miRNA probes
  8. ISH detection kits
  9. FISH probes
  10. FISH detection kits
  11. Blocking Reagents
  12. Automated instrument for IHC, ISH, FISH
  13. Covid-19 RT-PCR detection kit
  14. VTM

ISH- ISH has broad applications such as physical chromosome mapping, karyotyping, and pathogen profiling. Riboprobe also enables the localization and analysis of gene expression profile.

FISH- As a diagnostic tool, FISH is widely used in clinical genetics, neuroscience, reproductive medicine, toxicology, microbial ecology, evolutionary biology, comparative genomics, cellular genomics and chromosome biology to check for genetic abnormalities associated with prenatal diagnosis, cancer, birth defects and mental retardation. It is possible to differentiate benign and malignant tumors in the same tissue using FISH.


  • Chromogenic ISH: Bright field microscope
  • FISH: Fluorescence microscope

There are two basic approaches to visualize the DNA or RNA target sequences in situ: chromogenic in situ hybridization (CISH) and fluorescence in situ hybridization (FISH). While these approaches involve the same underlying principle, the instrumentation required to visualize the specimen is different.


The nucleic acids within a histologic specimen can be detected by the hybridization of a complementary nucleic acid probe in which a reporter molecule is attached. Common non-radioactive labels for probe are fluorescein and digoxigenin. Subsequent visualization of the reporter molecule localizes DNA or RNA sequences in tissue or cells samples.


In Situ Hybridization (ISH) is a powerful technique for precise detection and localization of a specific nucleic acid sequence within a histologic section.


  • Horseradish peroxidase (HRP)
  • Alkaline phosphatase

Antibody is conjugated to an enzyme, such as peroxidase, that can catalyze a color-producing reaction. Antibody can be tagged to a fluorophore, such as fluorescein (immunofluorescence)


These are foreign molecules to which the body may be exposed and respond with a reaction specifically and bind to the antigen. These are typically proteins or polysaccharides within or on the surface of cell.


These are antibodies against single epitope of single antigen


These are antibodies against many epitopes of one antigen


  1. Enzymatic/proteolytic antigen retrieval
  2. Heat-induced antigen retrieval method

The process of sample fixation can lead to protein cross-linking, which masks antigens and can restrict antigen-antibody binding. Antigen retrieval enables an antibody to access the target protein within the tissue.


Biogenex provides Dewax solution for deparaffinization. It is a non-toxic solution. Commonly Xylene is used but it is a toxic solution.


3-5µ


10% Neutral Buffered Formalin


  1. Baking
  2. Deparaffinization and rehydration
  3. Antigen Retrieval
  4. Peroxide Blocking/Endogenous peroxidaseblocking
  5. Power Blocking/Protein Blocking
  6. Primary Antibody
  7. Super Enhancer/Linker
  8. Poly-HRP/ Secondary Antibody/ Label
  9. DAB
  10. Counter staining
  11. Dehydration, Clearing and mounting

Note– If one is using one step poly HRP then “vii” point is not applicable.


Immunohistochemistry is used to help diagnose diseases, such as cancer. It may also be used to tell the difference between different types of cancer.


Immunohistochemistry is a well-established, highly specific and sensitive method that allows the localization of an antigen within a cell or any other biological tissue samples with high resolution. The bound antigen-antibody complexes are then visualized using chemically linked enzymes, dyes, or fluorescent labels.


Yes, it will be added based on Special request from customers-end and you need to contact BioGenex, Customer Service @ 1 800 421 4149, if not then FISH cannot be performed on Elite System.


No, Infinity will proceed without the barcodes slides and reagents scanning


Elite: No, only the Slides labels can be printed with i500 printer, whereas the Detection kit needs to be purchased from BioGenex only.


400 lb /182 Kg


Dimensions are 29 x 66 x 59 Inches


Yes, the Neutral to Earth Voltage should be always less than 2 Volts (AC) for the Medical instruments.


Yes, without any change user can plug the instrument power to 110V or 230V power Supply from UPS.


No, it’s always better to arrange from the User End.


Yes, either needs to connect to the Centralized UPS or the Separate UPS with 1500Watts. If the Power Failure rate is more then, it’s better to connect to longer UPS Back up.


XMatrx is developed and tested on Windows XP / Win 7 and Win 10. Currently providing with Win 10 Operating System


Graphical User Interface for Xmatrx is based on our popular i6000 interface. Xmatrx GUI expands the i6000 interface to enrich your programming experience. Main interface window displays the slide map and control panel. Slide map offers an intuitive and convenient way of selecting & editing slide protocols and to query the progress of a slide during the run.

Various operations are color-coded. Slide objects on the main window are displayed in appropriate colors based on their current operation making it convenient to get a snapshot of the run status from a distance. In the event of an error condition, system plays out an appropriate audio message and also visual message on the control panel.


Need for updates/bug fixes, if any, determines the frequency of new software releases.  There could be 1-2 releases every 10 – 12 months.


Instrument is calibrated before shipping out. While setting up the system, calibration must be checked. Once setup, re-calibration is not required for day-to-day operation. PM will address the calibration issues, if any.


Each PC that ships with XMatrx will be configured for remote access capability. If a PC is connected to Internet, with required access rights, remote diagnostic can be performed. 


Infinity: Xmatrx allows you to create your own protocols in addition to BioGenex supplied ones.

Elite: Being a closed system, Xmatrx Elite requires you to run all the protocols (BioGenex and User created) in a closed format. Once a protocol is scanned into a slide position, you can edit the allowed fields, if needed. Allowed fields are: Temperature, Incubation, Buffer Selection, number of Count &Micro Chamber sealing.


No. All consumables must be purchased from BioGenex only


Xmatrx System requires a Special Micro Chamber Slides with hydrophobic barrier, after oil sealing it canwith-stand longer incubation time and very minimal reagent usage. These slides are in 3 different Patterns (18 x 18mm, 25 x 25mm and 25 x 40mm). These slides need to be purchased from BioGenex only.


There are Two8 liter waste containers attached to the Xmatrx Instrument and for disposing the Waste need to follow the “Waste Management Process” specified as per the LAB standards or follow  any regular biohazard waste Procedure


Yes the Xmatrxä System will mount the slides using permanent mounting media. (Xmountä) Once the mounting media is applied it will also add the Coverslip


It is recommended that you prime the required solutions before every run for consistent staining quality. If it is not possible, you may want to prime the solutions whenever you make up new reagents or operate the system after a long period of inactivity (e.g., 2-3 days). This eliminates the air bubbles in the buffer lines and ensures continuous flow of the buffer solutions.


No. Xmatrx system displays the required buffers in the pre-run prime window. Disconnect the unused buffer lines from the system before starting a run.


Approximately 100 ml


Yes,pleasecontact BioGenex, Customer Service @ 1 800 421 4149.


Xmatrx system is designed to work with 3 different sizes of Coverslips:

  • 18 x 18 mm
  • 25 x 25 mm
  • 25 x 40 mm

No. System discards the tips and Coverslips after use. Reuse of these discarded tips and Coverslips is not recommended, as it will cause cross contamination and also damages the instrument functionality.


While applying large volumes (more than 100ul), Xmatrx system uses large tips. Typically, volume range for this step is 100-850ul. 


While processing expensive reagents like AR Solution, Antibody/Probe, Xmatrx system uses small tips. Typically, volume range for this step is 10-100ul.


Yes, for Xmatrx we have Consumable kit which has Barrier Slides, Small and Large Pipette tips and coverslips.

Please contact BioGenex, Customer Service @ 1 800 421 4149. 


Elite: No. The Xmatrx Elite is a closed system, which ensures that the user will have the best and optimal results using BioGenex detection systems.

Infinity: Yes, it’s open System.Can create a New Reagent, Antibody or increase the number of steps in the protocol or can create new Protocols also.


Xmatrx system can be programmed to use as much as 850ul. However, different applications & operations may have different maximums. Please refer to the protocol datasheet for volume information on a specific protocol.


Xmatrx system can be programmed to use as little as 10ul. However, different applications & operations may have different minimums. Please refer to the protocol datasheet for the volume information on a specific protocol.


Different vial types have different dead volumes:

  • 17 ml vials have a dead volume of 400ul
  • 2 ml vials  for ISH have a dead volume of 50ul 

When the system does not read the Reagent Vial, user may have the provision to add manually (enter the serial number) by selecting the reagent from the list. A reagent vial is entered into the list either or when the system reads the Barcoded vial for the first time. If the reagent does not exist in the database, the vial will have to be returned back to BioGenex, to be replaced by a new vial. Please contact BioGenex Technical Support @ 1 800 421 4149 for more information.


When the system does not read the slide barcode label, the user may manually select the protocol from the internal database of BioGenex protocols.


Yes. Please contact BioGenex’s, Customer Service @ +1 510 824 1400 


BioGenexsells Xviz detection system, which is be used to run all antibodies. The Xmatrx Elite is a closed system, which ensures that the user will have the best and optimal results using BioGenex detection systems. Xmatrx Infinity is an Open System, all the Detection kit and Antibodies can be used as per customer choice.


This allows the system to track reagent usage, lot numbers and expiry to ensure that the correct reagent is being used for Xmatrx Elite only.


BioGenex sells most of the antibody panels that are required in a clinical lab. In case, if any antibody is not available fromBioGenex, the User will have an option to buy an empty Barcoded vial to run their own Antibody for Elite. In Case of Infinity instrument 3rd Party Antibody can be used without the Barcoded vial.


< 2 Minutes


Yes. The slide heaters are individually temperature controlled.


Yes you can do antigen retrieval on the system.


No.  Xylene is not recommended, better to use BioGenex De-waxing solution.


Yes, the slides can be baked on the Xmatrx System @ 60°C for 1 hour and also you have the flexibility to adjust the Temperature and Time. Apart from this the protocol can be used for baking along with instrument starts and finishing the run.


You can order them through Customer Service +1 510 824 1400or email to customerservice@biogenex.com; or indiacs@biogenex.com or internationalcs@biogenex.com


Yes they just need to be placed in the slots on the base of the instrument.


BioGenex has designed the Slide racks for the Xmatrx System. The slides just need to be place into the Slide holder slot and then close the clip.


The best allowed temperature range for the instrument is 15°C to 30°C.


BioGenex Technical Support @ 1 510 824 1400 should be able to answer all your technical questions or customerservice@biogenex.com; or indiacs@biogenex.com or internationalcs@biogenex.com

You may also contact your local Sales Representative OR/and Application Specialist


BioGenex field Service engineer / trained distributor will perform Two PM’s per year


This includes just a basic cleaning of the instrument to prevent any contamination and to ensure proper functionality of the instrument. We recommend basic cleaning done by the user as per the Maintenance Chart.


Xmatrx Elite / Infinity is provided with a standalone systems. So the user will not require any extra bench space. The unit will be received as a cabinet with all the bulk reagents placed within it.


No the instrument does not need to be under a hood.


No you do not need to calibrate the instrument every time you use it. The instrument will be calibrated when it is installed. Re-calibration will be required if the instrument is moved to a different location.


BioGenex field service engineer will install the instrument. Your local sales repsentative and application scientist will be involved in training and optimizing your protocols on the instrument.


FFPE tissues, pap smears and cell smudges can be used with these probes.


We provide a universal detection kit for all probes (Super SensitiveTM One-Step ISH detection kit).


BioGenex probes are intended to use with Super SensitiveTM One Step ISH detection kit and optimized for chromogenic visualization under bright field microscopy. However, if the end-user wants to use any other kit and visualization technique, they need to validate their own protocol.


For the less no. of slides, if you are using BioGenex antigen retrieval solutions {HK546 (EZ-AR™ 1 Elegance ), HK547 (EZ-AR™ 2 Elegance)}, you can reuse these solutions up to 2-3 times.


Following are the solutions for doing Antigen Retrieval without EZ-RT System and Microwave-

  1. Water bath- Set the temp. of water bath at 100’C. Take one glass/plastic container and pour AR solution in it. Thereafter put the slides (with slide holder) in glass/ plastic container. After that put this container (having slides) into water bath for 30 mins. Make sure that the water bath water should not mix with the AR solution container. Heat at 100’C for 30-40 min and take out the container from water bath. Thereafter follow the regular IHC protocol.
  2. Hot plate- Set the temp. 100’C. Take AR solution in glass container and then put slides into glass container. Put that glass container at hot plate and heat for 30-40 min at 100’C. Thereafter follow the regular IHC protocol.

Note- Count the time of AR once AR solution temp reaches to 100’C. If it is not possible to reach to 100’C then it can be done at 98’C also.


The choice of mounting medium following immunochemical staining is largely dictated by the chromogen label used to visualize the antigen. Compatible Mounting Media for Chromogens and Counterstains

Counterstains AEC BCIP/NBT DAB Elegance Red Fast Red New Fuchsin
Hematoxylin Aqueous/ SuperMount Aqueous /Not recommended Aqueous/ Permanent/ SuperMount Aqueous/ Permanent/ SuperMount SuperMount / Aqueous SuperMount
Methyl Green Not recommended Permanent Permanent Permanent Permanent Permanent
Nuclear Fast Red Not recommended Aqueous/ Permanent/ SuperMount Aqueous/ Permanent/ SuperMount Not recommended Not recommended Not recommended

 


Most antibodies can be used either with DAB or AEC chromogen depending on the preference for staining under a light microscope.


The requirement of antigen retrieval depends on the antibody used and its staining protocol. For frozen and de-calcified tissues, heat-based antigen retrieval is NOT recommended. We provide alternate solutions for these kinds of tissues such as the Decal Retrieval Solution for acid-decalcified bone marrow tissue and enzymes for tissue digestion.


The proprietary technology used in the EZ-AR Elegance solutions provides stronger intensity and reproducible results. These solutions are designed for used with automated platforms such as Xmatrx systems and the EZ Retriever. The normal antigen solutions are intended for use with manual protocols.


Evaporation in Citra and Citra plus antigen retrieval solution is more and its ph also changes after use that’s why these can not be reused again and again.


For concentrated antibodies, the protein concentration is available on the data sheet for that specific antibody. Ready-to-Use (RTU) antibodies are pre-diluted for optimal staining results. We can provide the concentration of RTU antibodies upon request.


There are various reasons as to why we discontinue certain antibodies ranging from raw material issues to insufficient sales. The replacement products, if available, can be provided on request.


Most primary antibodies raised in mouse (IgG +IgM) and rabbit (IgG) work with our Poly-HRP Secondary antibody. In case of primary antibodies raised in other species, we also provide species-specific secondary antibodies for use with our Link-Label System.


The one-step detection kit is designed with proprietary technology which eliminates the use of Super Enhancer required by the two-step detection kit. Therefore, the one-step kit provides superior sensitivity and specificity with the advantage of a short protocol.


Two years from date of manufacture when stored according to the product information page.


The detection kits are designed for use in human tissue. However, the Super SensitiveTM Link-Label IHC detection system comes in a choice of kit formats designed for use with human, animal or rodent tissue.


BioGenex antibodies are tested and validated for IHC. For any procedure or technique apart from IHC, the protocol must be validated by the user.


Yes, BioGenex detection kits are universal detection systems for mouse and rabbit antibodies.


Yes, most of our antibodies come in manual and automation packs and can be used for both purposes.


All of our antibodies can be used with the following detection kits provided by BioGenex:

Super Sensitive Polymer-IHC Detection System
Super Sensitive One-Step Polymer-HRP Detection System
Super Sensitive Link-Label IHC Detection System


BioGenex antibodies are validated and intended for use on human FFPE and frozen tissues. If used on tissues from other species, the protocol must be validated by the end user.


While using the EZ-Retriever®System for antigen retrieval, you have the facility to increase and decrease the temp and time according to your need. You can use 107 Deg C maximum temperature and 15 mins maximum time in one cycle with BioGenex antigen retrieval solutions {HK521 (EZ-AR™ 1), HK546 (EZ-AR™ 1 Elegance), HK522(EZ-AR™ 2), HK547 (EZ-AR™ 2 Elegance)}. If you are using other solutions then you can use it at 95 Deg C for 10 min in one cycle.


BioGenex provides information on the specific antigen retrieval solution recommended for use with its primary antibodies. We offer Retrievit Sampler Kit for use with primary antibodies from other manufacturers. This kit provides the customer with five different antigen retrieval solutions so the user can determine which one is the best for that particular antibody.


The microwave pressure cooker method is a procedure that utilizes a microwave with a pressure cooker for antigen retrieval and staining. The pressure cooker sold by BioGenex is especially designed for use in a microwave oven. Its advantages include the speed of treatment, reproducibility of results with large batches of slides, ability to use metal slide racks, and economy of equipment costs.


STAT (Latin: statum, meaning: to rush, urgent) Access allows the addition of emergency specimen slides for staining during an ongoing run. STAT slides will be processed and completed at the highest priority. During the processing of STAT slides, all other slides being processed shall remain on hold and are buffered regularly to keep the tissue hydrated. After completion of the STAT slides, all pending slides that are on hold will be processed according to their protocol.


Most autostainers on the market do not allow for the addition of new samples for staining when a run is in progress. Xmatrx Diagnostics breaks this limitation by enabling continuous operation of the system. The user can add new slides in the middle of a run if empty slide positions are available. The slides that are loaded in continuous mode will be processed along with the current slides without affecting the current run. Continuous Access enables the user to remove completed slides and load new ones without the need to wait for run completion. In addition, reagents that are no longer required can be removed and new ones can be added.